Search results

Search for "dosimeters" in Full Text gives 4 result(s) in Beilstein Journal of Organic Chemistry.

Detection of therapeutic radiation in three-dimensions

  • John A. Adamovics

Beilstein J. Org. Chem. 2017, 13, 1325–1331, doi:10.3762/bjoc.13.129

Graphical Abstract
  • leuco dye, which is radiolytically oxidized to a dye absorbing at 630 nm. Keywords: dosimeters; leuco dyes; polymers; radiation; triarylmethane synthesis; Introduction Radiotherapy treatment is a complex 3D process, which is the principle treatment modality for most cancers [1]. The two main types of
  • (dosimeters) with sufficient capability to verify complex treatments and ensure accurate, safe implementation [2]. There have been reports of high failure rates for complex radiation treatments [3][4]. These concerns and others have led many to recognize an urgent need to strengthen the foundations of quality
  • the polymerization of acrylamide with N,N’-methylenebisacrylamide and various monomers to yield a cloud like precipitate in the aqueous gel [13]. Due to the nature of their radical chemistry, polymer gel dosimeters have several limitations. They are susceptible to atmospheric oxygen inhibiting the
PDF
Album
Review
Published 05 Jul 2017

A simple and efficient dual optical signaling chemodosimeter for toxic Hg(II)

  • Sabir H. Mashraqui,
  • Sapna A. Tripathi,
  • Sushil S. Ghorpade and
  • Smita R. Britto

Beilstein J. Org. Chem. 2012, 8, 1352–1357, doi:10.3762/bjoc.8.155

Graphical Abstract
  • ]. Lately, the chemodosimeter-based sensing has gained increasing popularity on account of the irreversible chemical intervention of analytes with the probe molecules. Since the metal ions are disengaged from the chemically modified dosimeters, the process results in the more reliable fluorescence
PDF
Album
Supp Info
Full Research Paper
Published 22 Aug 2012

SbCl3-catalyzed one-pot synthesis of 4,4′-diaminotriarylmethanes under solvent-free conditions: Synthesis, characterization, and DFT studies

  • Ghasem Rezanejade Bardajee

Beilstein J. Org. Chem. 2011, 7, 135–144, doi:10.3762/bjoc.7.19

Graphical Abstract
  • ]. They are also used in low-dose dosimeters [7], in chemical radiochromic dosimeters [8] and as sensitizers for photoconductivity [9]. The leuco forms of triarylmethine dyes are extensively used in biological applications. They show phototoxicity toward tumor cells [10] and also demonstrate antifungal
PDF
Album
Full Research Paper
Published 31 Jan 2011

ROMP-Derived cyclooctene-based monolithic polymeric materials reinforced with inorganic nanoparticles for applications in tissue engineering

  • Franziska Weichelt,
  • Solvig Lenz,
  • Stefanie Tiede,
  • Ingrid Reinhardt,
  • Bernhard Frerich and
  • Michael R. Buchmeiser

Beilstein J. Org. Chem. 2010, 6, 1199–1205, doi:10.3762/bjoc.6.137

Graphical Abstract
  • Fricke-dosimetry. The reliability of the dose determination was checked against IAEA-alanine dosimeters resulting in an overall accuracy of the dose measurements of ±5%. The total dose applied was 24 kGy. Cell proliferation assay Tests were made in 24-well-plates and 6-well-plates with a well diameter of
PDF
Album
Supp Info
Full Research Paper
Published 17 Dec 2010
Other Beilstein-Institut Open Science Activities