Search results

Search for "high-performance liquid chromatography" in Full Text gives 32 result(s) in Beilstein Journal of Nanotechnology.

DNA–melamine hybrid molecules: from self-assembly to nanostructures

  • Rina Kumari,
  • Shib Shankar Banerjee,
  • Anil K. Bhowmick and
  • Prolay Das

Beilstein J. Nanotechnol. 2015, 6, 1432–1438, doi:10.3762/bjnano.6.148

Graphical Abstract
  • phosphoramidation cross coupling was confirmed by polyacrylamide gel electrophoresis (PAGE), reversed phase high performance liquid chromatography (RP-HPLC), matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) mass spectrometry (MS). The reaction products were purified by dialysis
PDF
Album
Supp Info
Letter
Published 30 Jun 2015

From lithium to sodium: cell chemistry of room temperature sodium–air and sodium–sulfur batteries

  • Philipp Adelhelm,
  • Pascal Hartmann,
  • Conrad L. Bender,
  • Martin Busche,
  • Christine Eufinger and
  • Juergen Janek

Beilstein J. Nanotechnol. 2015, 6, 1016–1055, doi:10.3762/bjnano.6.105

Graphical Abstract
PDF
Album
Review
Published 23 Apr 2015

Purification of ethanol for highly sensitive self-assembly experiments

  • Kathrin Barbe,
  • Martin Kind,
  • Christian Pfeiffer and
  • Andreas Terfort

Beilstein J. Nanotechnol. 2014, 5, 1254–1260, doi:10.3762/bjnano.5.139

Graphical Abstract
  • high-performance liquid chromatography (HPLC), suffers from the drawback that the purification procedure is not specific for sulfur-containing contaminations. While these contaminations might only play a minor role in most cases of SAM formation, where thermodynamic equilibrium can be approached by
PDF
Album
Supp Info
Full Research Paper
Published 12 Aug 2014

Pyrite nanoparticles as a Fenton-like reagent for in situ remediation of organic pollutants

  • Carolina Gil-Lozano,
  • Elisabeth Losa-Adams,
  • Alfonso F.-Dávila and
  • Luis Gago-Duport

Beilstein J. Nanotechnol. 2014, 5, 855–864, doi:10.3762/bjnano.5.97

Graphical Abstract
  • value of the order of 4–5, where Fenton reaction is far more efficient. Consequently, special pH control is not required. This it shown in Figure 7, for experiments performed with two different concentration values of dye and pyrite nanoparticle loads. We used high performance liquid chromatography
  • times of the process. The degradation of CuPc was analyzed by high performance liquid chromatography (HPLC; Waters Alliance 2975 equipped with a Waters 996 Photodiode Array Detector; UV–vis detection), using a C8 column (Waters Symmetry: 150 × 4.6 mm, 3.5 μm). The mobile phases were 0.1% aq phosphoric
PDF
Album
Full Research Paper
Published 16 Jun 2014

Extracellular biosynthesis of gadolinium oxide (Gd2O3) nanoparticles, their biodistribution and bioconjugation with the chemically modified anticancer drug taxol

  • Shadab Ali Khan,
  • Sanjay Gambhir and
  • Absar Ahmad

Beilstein J. Nanotechnol. 2014, 5, 249–257, doi:10.3762/bjnano.5.27

Graphical Abstract
  • ) and X-ray photoemission spectroscopy (XPS). The Gd2O3–taxol bioconjugate was confirmed by UV–vis spectroscopy and fluorescence microscopy and was purified by using high performance liquid chromatography (HPLC). Keywords: bioconjugation; biodistribution; gadolinium oxide; humicola sp; transmission
PDF
Album
Full Research Paper
Published 07 Mar 2014

Optimization of solution-processed oligothiophene:fullerene based organic solar cells by using solvent additives

  • Gisela L. Schulz,
  • Marta Urdanpilleta,
  • Roland Fitzner,
  • Eduard Brier,
  • Elena Mena-Osteritz,
  • Egon Reinold and
  • Peter Bäuerle

Beilstein J. Nanotechnol. 2013, 4, 680–689, doi:10.3762/bjnano.4.77

Graphical Abstract
  • 60, mesh 0.063–0.2 μm, were used for column chromatography. High performance liquid chromatography was performed on a Hitachi instrument equipped with a UV–vis detector L-7420, columns (Nucleosil 100-5 NO2 with a pore size of 100 Å) from Machery-Nagel using a dichlormethane/n-hexane mixture (40:60
  • performance liquid chromatography (see Supporting Information File 1). Mp 204 °C (onset DSC). 1H NMR, 13C NMR, MALDI-TOF, and elemental analysis were all consistent with the previously reported values [20]. Device fabrication: Photovoltaic devices were made following a previously reported procedure [33], with
  • butyl-substituted terthiophene 5 in a two-fold Pd(0)-catalyzed Stille-type coupling reaction to obtain DCV5T-Bu4 on the gram scale in 46% yield. After purification by column chromatography, the high purity and thermal stability of oligomer DCV5T-Bu4 were confirmed by analytical high performance liquid
PDF
Album
Supp Info
Full Research Paper
Published 24 Oct 2013

Glassy carbon electrodes modified with multiwalled carbon nanotubes for the determination of ascorbic acid by square-wave voltammetry

  • Sushil Kumar and
  • Victoria Vicente-Beckett

Beilstein J. Nanotechnol. 2012, 3, 388–396, doi:10.3762/bjnano.3.45

Graphical Abstract
  • reliability of the SWV method was validated by conducting parallel experiments based on high-performance liquid chromatography (HPLC) with absorbance detection. The observed mean AA contents of the commercial orange juice samples obtained by the two methods were compared statistically and were found to have
PDF
Album
Full Research Paper
Published 10 May 2012
Other Beilstein-Institut Open Science Activities