Search results

Search for "electrospray ionization" in Full Text gives 132 result(s) in Beilstein Journal of Organic Chemistry.

Mutational analysis of a phenazine biosynthetic gene cluster in Streptomyces anulatus 9663

  • Orwah Saleh,
  • Katrin Flinspach,
  • Lucia Westrich,
  • Andreas Kulik,
  • Bertolt Gust,
  • Hans-Peter Fiedler and
  • Lutz Heide

Beilstein J. Org. Chem. 2012, 8, 501–513, doi:10.3762/bjoc.8.57

Graphical Abstract
  • B in 15 min (solvent A: water/formic acid (999:1); solvent B: acetonitrile/formic acid (999.4:0.6)). Detection was carried out at 230, 260, 280, 360, and 435 nm. Electrospray ionization (positive and negative ionization) in Ultra Scan mode with capillary voltage of 3.5 kV and drying gas temperature
PDF
Album
Supp Info
Full Research Paper
Published 04 Apr 2012

Self-assembly of Ru4 and Ru8 assemblies by coordination using organometallic Ru(II)2 precursors: Synthesis, characterization and properties

  • Sankarasekaran Shanmugaraju,
  • Dipak Samanta and
  • Partha Sarathi Mukherjee

Beilstein J. Org. Chem. 2012, 8, 313–322, doi:10.3762/bjoc.8.34

Graphical Abstract
  • salts in high yields and were characterized fully by multinuclear (1H, 13C and 19F) NMR, infrared (IR) and electrospray ionization mass spectrometry (ESIMS). In addition, the molecular structure of macrocycle 2a was established unequivocally by single-crystal X-ray diffraction analysis and adopts a
  • information about the exact composition and nuclearity of the final products. Electrospray ionization mass spectrometry (ESIMS) can be used as a soft-ionization method to elucidate the exact composition of the product [12]. The ESIMS analysis confirmed the formation of the rather unexpected [2 + 1] self
PDF
Album
Supp Info
Full Research Paper
Published 28 Feb 2012

Valence isomerization of cyclohepta-1,3,5-triene and its heteroelement analogues

  • Helen Jansen,
  • J. Chris Slootweg and
  • Koop Lammertsma

Beilstein J. Org. Chem. 2011, 7, 1713–1721, doi:10.3762/bjoc.7.201

Graphical Abstract
  • + 2] cycloadditions of the in situ generated singlet phosphinidene 35 with olefins or acetylenes (Scheme 7) [5][6][7][8][9]. This approach has even lead to the detection of the transient phosphinidene species by employing electrospray ionization tandem mass spectrometry (ESIMS/MS); its gas-phase
PDF
Album
Review
Published 21 Dec 2011

Synthesis and self-assembly of 1-deoxyglucose derivatives as low molecular weight organogelators

  • Guijun Wang,
  • Hao Yang,
  • Sherwin Cheuk and
  • Sherman Coleman

Beilstein J. Org. Chem. 2011, 7, 234–242, doi:10.3762/bjoc.7.31

Graphical Abstract
  • using a 400 MHz Varian NMR spectrometer. High resolution mass spectrometry data were measured on the Q-Tof of the Mass Spectrometry lab at the University of Illinois after the low resolution masses were confirmed. The ionization technique used was ESI (electrospray ionization). Melting points were
PDF
Album
Supp Info
Full Research Paper
Published 21 Feb 2011

Templated versus non-templated synthesis of benzo-21-crown-7 and the influence of substituents on its complexing properties

  • Wei Jiang and
  • Christoph A. Schalley

Beilstein J. Org. Chem. 2010, 6, No. 14, doi:10.3762/bjoc.6.14

Graphical Abstract
  • coupling constants (J) are in Hertz. The following abbreviations were used for signal multiplicities: s, singlet; d, doublet; t triplet; m, multiplet. Electrospray-ionization time-of-flight high-resolution mass spectrometry (ESI-TOF-HRMS) experiments were conducted on an Agilent 6210 ESI-TOF, Agilent
  • Technologies and a Varian/IonSpec QFT-7 FTICR (Fourier-transform ion-cyclotron-resonance) mass spectrometer equipped with a superconducting 7 Tesla magnet and a micromass Z-spray Electrospray-ionization (ESI) ion source utilizing a stainless steel capillary with a 0.75 mm inner diameter. 2-{2-[2-(2-{2-[2-(2
PDF
Album
Supp Info
Full Research Paper
Published 11 Feb 2010

Synthesis of phosphonate and phostone analogues of ribose-1-phosphates

  • Pitak Nasomjai,
  • David O'Hagan and
  • Alexandra M. Z. Slawin

Beilstein J. Org. Chem. 2009, 5, No. 37, doi:10.3762/bjoc.5.37

Graphical Abstract
  • . Infra red (IR) spectra were recorded on Nicolet Avatar 360 FT-IR. High resolution mass spectrometry (HRMS) was carried out using a Micromass LCT (Manchester, UK) mass spectrometer with electrospray ionization (ESI) operating in positive and negative modes. Optical rotations were measured on Perkin-Elmer
PDF
Album
Supp Info
Full Research Paper
Published 27 Jul 2009

Synthesis of methylenebisamides using CC- or DCMT- activated DMSO

  • Qiang Wang,
  • Lili Sun,
  • Yu Jiang and
  • Chunbao Li

Beilstein J. Org. Chem. 2008, 4, No. 51, doi:10.3762/bjoc.4.51

Graphical Abstract
  • DMSO-d6 or CDCl3 (13C). Mass spectra were obtained using an LCQ Advantage MAX ion trap mass spectrometer equipped with electrospray ionization (ESI) ion source or a Thermo Finnigan TRACE-DSQ spectrometer. Elemental analyses for C, H and N were performed on a Yanaco CHNCORNER MF-3 elemental analyzer
PDF
Album
Supp Info
Full Research Paper
Published 15 Dec 2008
Other Beilstein-Institut Open Science Activities