Search results

Search for "transmission electron microscopy (TEM)" in Full Text gives 452 result(s) in Beilstein Journal of Nanotechnology. Showing first 200.

Ceria/polymer nanocontainers for high-performance encapsulation of fluorophores

  • Kartheek Katta,
  • Dmitry Busko,
  • Yuri Avlasevich,
  • Katharina Landfester,
  • Stanislav Baluschev and
  • Rafael Muñoz-Espí

Beilstein J. Nanotechnol. 2019, 10, 522–530, doi:10.3762/bjnano.10.53

Graphical Abstract
  • groups per nm2 was obtained for samples NC and NC(Ar). Transmission electron microscopy (TEM) was carried out with a Jeol 1400 microscope at an acceleration voltage of 200 kV. Samples for TEM observation were prepared by dropping the diluted dispersions on carbon-coated copper grids and dried. Scanning
PDF
Album
Supp Info
Full Research Paper
Published 22 Feb 2019

Reduced graphene oxide supported C3N4 nanoflakes and quantum dots as metal-free catalysts for visible light assisted CO2 reduction

  • Md Rakibuddin and
  • Haekyoung Kim

Beilstein J. Nanotechnol. 2019, 10, 448–458, doi:10.3762/bjnano.10.44

Graphical Abstract
  • , X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, field emission scanning electron microscopy, transmission electron microscopy (TEM), and UV–vis spectroscopy. High-resolution TEM images clearly show that C3N4 QDs (average diameter of 2–3 nm) and NFs (≈20–45 nm) are
PDF
Album
Supp Info
Full Research Paper
Published 13 Feb 2019

Gold nanoparticles embedded in a polymer as a 3D-printable dichroic nanocomposite material

  • Lars Kool,
  • Anton Bunschoten,
  • Aldrik H. Velders and
  • Vittorio Saggiomo

Beilstein J. Nanotechnol. 2019, 10, 442–447, doi:10.3762/bjnano.10.43

Graphical Abstract
  • brownish reflection and a purple transmission (Figure 1a). The nanoparticle solution was studied by transmission electron microscopy (TEM), showing that it was composed of polydisperse elongated nanoparticles of 50–60 nm with a mean aspect ratio of 1.4 (Figure 1b and Supporting Information File 1, Figure
PDF
Album
Supp Info
Full Research Paper
Published 12 Feb 2019

Improving control of carbide-derived carbon microstructure by immobilization of a transition-metal catalyst within the shell of carbide/carbon core–shell structures

  • Teguh Ariyanto,
  • Jan Glaesel,
  • Andreas Kern,
  • Gui-Rong Zhang and
  • Bastian J. M. Etzold

Beilstein J. Nanotechnol. 2019, 10, 419–427, doi:10.3762/bjnano.10.41

Graphical Abstract
  • microscope (Philips XL30 FEG, 30 kV) equipped with an EDAX X-ray detector. Transmission electron microscopy (TEM) images were captured using a JEOL JEM-2100F microscope operated at 200 kV. The TEM samples were prepared by placing a drop of catalyst powder dispersion in deionized water onto a carbon-coated Au
PDF
Album
Supp Info
Full Research Paper
Published 11 Feb 2019

Integration of LaMnO3+δ films on platinized silicon substrates for resistive switching applications by PI-MOCVD

  • Raquel Rodriguez-Lamas,
  • Dolors Pla,
  • Odette Chaix-Pluchery,
  • Benjamin Meunier,
  • Fabrice Wilhelm,
  • Andrei Rogalev,
  • Laetitia Rapenne,
  • Xavier Mescot,
  • Quentin Rafhay,
  • Hervé Roussel,
  • Michel Boudard,
  • Carmen Jiménez and
  • Mónica Burriel

Beilstein J. Nanotechnol. 2019, 10, 389–398, doi:10.3762/bjnano.10.38

Graphical Abstract
  • nanostructure growth was further analyzed in cross section by transmission electron microscopy (TEM), a JEOL 2011 equipment operating at 200 kV with a 0.19 nm point-to-point resolution. X-ray absorption near-edge spectroscopy (XANES) spectra at the Mn K-edge of LMO thin films were collected at the ESRF ID12
PDF
Album
Supp Info
Full Research Paper
Published 07 Feb 2019

Sub-wavelength waveguide properties of 1D and surface-functionalized SnO2 nanostructures of various morphologies

  • Venkataramana Bonu,
  • Binaya Kumar Sahu,
  • Arindam Das,
  • Sankarakumar Amirthapandian,
  • Sandip Dhara and
  • Harish C. Barshilia

Beilstein J. Nanotechnol. 2019, 10, 379–388, doi:10.3762/bjnano.10.37

Graphical Abstract
  • scanning electron microscopy (FESEM; Zeiss SUPRA 55) images. The crystallographic information of the NWs was investigated with the aid of transmission electron microscopy (TEM; Zeiss Libra 200). Micro-Raman spectroscopy (InVia, Reinshaw) at 514.5 nm excitation, with a 1800 grooves/mm grating, and
PDF
Album
Supp Info
Full Research Paper
Published 07 Feb 2019

A Ni(OH)2 nanopetals network for high-performance supercapacitors synthesized by immersing Ni nanofoam in water

  • Donghui Zheng,
  • Man Li,
  • Yongyan Li,
  • Chunling Qin,
  • Yichao Wang and
  • Zhifeng Wang

Beilstein J. Nanotechnol. 2019, 10, 281–293, doi:10.3762/bjnano.10.27

Graphical Abstract
  • an X-ray energy dispersive spectroscope (EDS) and a transmission electron microscopy (TEM, JEOL JEM-2100). The preparation process of the TEM sample was as follows: Firstly, the active materials were scraped off with a knife. Then the materials were dispersed in ethanol with ultrasonic vibration
PDF
Album
Full Research Paper
Published 25 Jan 2019

Relation between thickness, crystallite size and magnetoresistance of nanostructured La1−xSrxMnyO3±δ films for magnetic field sensors

  • Rasuole Lukose,
  • Valentina Plausinaitiene,
  • Milita Vagner,
  • Nerija Zurauskiene,
  • Skirmantas Kersulis,
  • Virgaudas Kubilius,
  • Karolis Motiejuitis,
  • Birute Knasiene,
  • Voitech Stankevic,
  • Zita Saltyte,
  • Martynas Skapas,
  • Algirdas Selskis and
  • Evaldas Naujalis

Beilstein J. Nanotechnol. 2019, 10, 256–261, doi:10.3762/bjnano.10.24

Graphical Abstract
  • electron microscopy (TEM) analysis (Figure 1a,b) shows the column-like growth with larger dimensions and more dense, close packing of the crystallites for the II series. Film composition, structure and surface morphology Figure 2a–c presents scanning electron microscopy (SEM) images of the films with
  • series of films of variable thickness were deposited: I – one source with LSMO solution, II – 2 separate sources, LSMO solution and solvent source (Figure 1). The growth rate was controlled by application of additional solvent, resulting in the dilution of the precursor in the gas phase. The transmission
PDF
Album
Letter
Published 23 Jan 2019

Thermal control of the defunctionalization of supported Au25(glutathione)18 catalysts for benzyl alcohol oxidation

  • Zahraa Shahin,
  • Hyewon Ji,
  • Rodica Chiriac,
  • Nadine Essayem,
  • Franck Rataboul and
  • Aude Demessence

Beilstein J. Nanotechnol. 2019, 10, 228–237, doi:10.3762/bjnano.10.21

Graphical Abstract
  • S1, Supporting Information File 1). The transmission electron microscopy (TEM) image shows that the ZrO2 particles have a diameter of around 50 nm. Au25(SG)18 was synthesized according to a reported method [33]. The characterization of the clusters by UV–vis spectroscopy shows two absorption peaks
  • °C) in a 70 µL alumina crucible, under air. The final temperature was maintained for 12 hours. Transmission electron microscopy (TEM) was carried out on a JEOL 2010 LaB6 microscope operating at 200 kV. The samples were prepared on a copper grid for analysis. The measurement of the diameter of the
PDF
Album
Supp Info
Full Research Paper
Published 18 Jan 2019

Study of silica-based intrinsically emitting nanoparticles produced by an excimer laser

  • Imène Reghioua,
  • Mattia Fanetti,
  • Sylvain Girard,
  • Diego Di Francesca,
  • Simonpietro Agnello,
  • Layla Martin-Samos,
  • Marco Cannas,
  • Matjaz Valant,
  • Melanie Raine,
  • Marc Gaillardin,
  • Nicolas Richard,
  • Philippe Paillet,
  • Aziz Boukenter,
  • Youcef Ouerdane and
  • Antonino Alessi

Beilstein J. Nanotechnol. 2019, 10, 211–221, doi:10.3762/bjnano.10.19

Graphical Abstract
  • produced nanoparticles, we recorded transmission electron microscopy (TEM) and scanning transmission electron microscope (STEM) images of the samples. Figure 3a illustrates the TEM image recorded for the same nanoparticles previously studied by EDX and SEM (red square named 1 in Figure 1a. Figure 3b
PDF
Album
Full Research Paper
Published 16 Jan 2019

pH-mediated control over the mesostructure of ordered mesoporous materials templated by polyion complex micelles

  • Emilie Molina,
  • Mélody Mathonnat,
  • Jason Richard,
  • Patrick Lacroix-Desmazes,
  • Martin In,
  • Philippe Dieudonné,
  • Thomas Cacciaguerra,
  • Corine Gérardin and
  • Nathalie Marcotte

Beilstein J. Nanotechnol. 2019, 10, 144–156, doi:10.3762/bjnano.10.14

Graphical Abstract
  • empty capillary. Transmission electron microscopy (TEM) images were acquired on microtomed samples (slices of ≈70 nm thickness) with a JEOL 1200 EX II instrument operating at 120 kV. Material characterization by scanning electron microscopy (SEM) was done on a HITACHI S4800 (FEG-HR) apparatus operating
PDF
Album
Supp Info
Full Research Paper
Published 11 Jan 2019

Wet chemistry route for the decoration of carbon nanotubes with iron oxide nanoparticles for gas sensing

  • Hussam M. Elnabawy,
  • Juan Casanova-Chafer,
  • Badawi Anis,
  • Mostafa Fedawy,
  • Mattia Scardamaglia,
  • Carla Bittencourt,
  • Ahmed S. G. Khalil,
  • Eduard Llobet and
  • Xavier Vilanova

Beilstein J. Nanotechnol. 2019, 10, 105–118, doi:10.3762/bjnano.10.10

Graphical Abstract
  • chemical composition of the iron oxide decorated carbon nanotube samples were investigated employing transmission electron microscopy (TEM), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). The differently decorated CNT samples were used to make gas sensors for detecting nitrogen dioxide. A
PDF
Album
Supp Info
Full Research Paper
Published 09 Jan 2019

Amorphous NixCoyP-supported TiO2 nanotube arrays as an efficient hydrogen evolution reaction electrocatalyst in acidic solution

  • Yong Li,
  • Peng Yang,
  • Bin Wang and
  • Zhongqing Liu

Beilstein J. Nanotechnol. 2019, 10, 62–70, doi:10.3762/bjnano.10.6

Graphical Abstract
  • crystallographic texture, scanning electron microscopy (SEM, JSM-5900 LV, JEOV) for micro-morphology, transmission electron microscopy (TEM, Tecnai G2 F20 S-TWIN) for microstructure, UV–vis diffuse reflectance spectroscopy (UV2100) for photoabsorption properties, X-ray photoelectron spectroscopy (XPS, Escalab
PDF
Album
Supp Info
Full Research Paper
Published 07 Jan 2019

Surface plasmon resonance enhancement of photoluminescence intensity and bioimaging application of gold nanorod@CdSe/ZnS quantum dots

  • Siyi Hu,
  • Yu Ren,
  • Yue Wang,
  • Jinhua Li,
  • Junle Qu,
  • Liwei Liu,
  • Hanbin Ma and
  • Yuguo Tang

Beilstein J. Nanotechnol. 2019, 10, 22–31, doi:10.3762/bjnano.10.3

Graphical Abstract
  • the GNRs and GNR@CdSe/ZnS was characterized using transmission electron microscopy (TEM), and the results are shown in Figure 3a and 3b. The average diameter of the CdSe/ZnS QDs is 8 ± 1 nm, where the corresponding TEM image is shown in Supporting Information File 1, Figure S2. The aspect ratio
PDF
Album
Supp Info
Full Research Paper
Published 03 Jan 2019

Zn/F-doped tin oxide nanoparticles synthesized by laser pyrolysis: structural and optical properties

  • Florian Dumitrache,
  • Iuliana P. Morjan,
  • Elena Dutu,
  • Ion Morjan,
  • Claudiu Teodor Fleaca,
  • Monica Scarisoreanu,
  • Alina Ilie,
  • Marius Dumitru,
  • Cristian Mihailescu,
  • Adriana Smarandache and
  • Gabriel Prodan

Beilstein J. Nanotechnol. 2019, 10, 9–21, doi:10.3762/bjnano.10.2

Graphical Abstract
  • front of a monochromatic X-ray beam having a variable incidence θ angle and a constant wavelength corresponding to the Kα copper line (λ = 1.5418 Å). Transmission electron microscopy (TEM and HRTEM) using a Tecnai F30 G2 (300 kV) instrument, was used to investigate the particle morphology, as well as
PDF
Album
Full Research Paper
Published 02 Jan 2019

Characterization and influence of hydroxyapatite nanopowders on living cells

  • Przemyslaw Oberbek,
  • Tomasz Bolek,
  • Adrian Chlanda,
  • Seishiro Hirano,
  • Sylwia Kusnieruk,
  • Julia Rogowska-Tylman,
  • Ganna Nechyporenko,
  • Viktor Zinchenko,
  • Wojciech Swieszkowski and
  • Tomasz Puzyn

Beilstein J. Nanotechnol. 2018, 9, 3079–3094, doi:10.3762/bjnano.9.286

Graphical Abstract
  • an in-house procedure [32]. Specific surface area The specific surface area (SSA) of the samples was determined through the Brunauer–Emmett–Teller (BET) method (AccuPyc, model Gemini 2360; Micromeritics Gosford, Australia). Transmission electron microscopy Transmission electron microscopy (TEM, JEOL
PDF
Album
Full Research Paper
Published 27 Dec 2018

A novel polyhedral oligomeric silsesquioxane-modified layered double hydroxide: preparation, characterization and properties

  • Xianwei Zhang,
  • Zhongzhu Ma,
  • Hong Fan,
  • Carla Bittencourt,
  • Jintao Wan and
  • Philippe Dubois

Beilstein J. Nanotechnol. 2018, 9, 3053–3068, doi:10.3762/bjnano.9.284

Graphical Abstract
  • -ray excitation source. Transmission electron microscopy (TEM) images were recorded on an HT-7700 microscope with an acceleration voltage of 100.0 kV and bright-field illumination. The samples were dispersed in methanol/water mixed solvent, dropped onto carbon-coated copper grid and dried in a fume
PDF
Album
Full Research Paper
Published 19 Dec 2018

A new bioinspired method for pressure and flow sensing based on the underwater air-retaining surface of the backswimmer Notonecta

  • Matthias Mail,
  • Adrian Klein,
  • Horst Bleckmann,
  • Anke Schmitz,
  • Torsten Scherer,
  • Peter T. Rühr,
  • Goran Lovric,
  • Robin Fröhlingsdorf,
  • Stanislav N. Gorb and
  • Wilhelm Barthlott

Beilstein J. Nanotechnol. 2018, 9, 3039–3047, doi:10.3762/bjnano.9.282

Graphical Abstract
  • the number and the distribution of setae showed differences across 11 surface sections, defined according to Wachmann [17], and to variations in the hair density (Figure 2). Both Notonecta species differed slightly in the number and distribution of setae. Transmission electron microscopy (TEM
PDF
Album
Supp Info
Full Research Paper
Published 14 Dec 2018

Colloidal chemistry with patchy silica nanoparticles

  • Pierre-Etienne Rouet,
  • Cyril Chomette,
  • Laurent Adumeau,
  • Etienne Duguet and
  • Serge Ravaine

Beilstein J. Nanotechnol. 2018, 9, 2989–2998, doi:10.3762/bjnano.9.278

Graphical Abstract
  •  3b). Nevertheless, the determination of the assembly yield by statistical analysis of the transmission electron microscopy (TEM) images was not possible, because CMs with a low amount of satellites could be removed with the excess of satellites during this purification step, leading distorted
  • collected by three cycles of centrifugation (500g; 20 min) and redispersion in ethanol. Characterization techniques Transmission electron microscopy (TEM) TEM experiments were performed using a Hitachi H600 microscope operating at an acceleration voltage of 75 kV and a JEOL JEM 1400 Plus microscope
PDF
Album
Full Research Paper
Published 06 Dec 2018

The nanoscaled metal-organic framework ICR-2 as a carrier of porphyrins for photodynamic therapy

  • Jan Hynek,
  • Sebastian Jurík,
  • Martina Koncošová,
  • Jaroslav Zelenka,
  • Ivana Křížová,
  • Tomáš Ruml,
  • Kaplan Kirakci,
  • Ivo Jakubec,
  • František Kovanda,
  • Kamil Lang and
  • Jan Demel

Beilstein J. Nanotechnol. 2018, 9, 2960–2967, doi:10.3762/bjnano.9.275

Graphical Abstract
  • diffraction measurements (XRD), transmission electron microscopy (TEM), and dynamic light scattering (DLS). The powder XRD pattern depicted in Figure 4 clearly corresponds to the ICR-2 phase [25]. The size of the coherent diffraction domains of 29 nm was calculated from the broadening of the 110 and 020
  • ]. UV–vis absorption spectra of the dispersions were recorded on a Perkin Elmer Lambda 35 spectrometer. High-resolution transmission electron microscopy (TEM) was carried out on a JEOL JEM 3010 microscope operated at 300 kV (LaB6 cathode, point resolution 1.7 Å) with an Oxford Instruments Energy
PDF
Album
Supp Info
Full Research Paper
Published 30 Nov 2018

Hybrid Au@alendronate nanoparticles as dual chemo-photothermal agent for combined cancer treatment

  • Anouchka Plan Sangnier,
  • Romain Aufaure,
  • Laurence Motte,
  • Claire Wilhelm,
  • Erwann Guenin and
  • Yoann Lalatonne

Beilstein J. Nanotechnol. 2018, 9, 2947–2952, doi:10.3762/bjnano.9.273

Graphical Abstract
  • special attention to alendronate release under photothermal activation. Au@alendronate NPs characterization: (a) transmission electron microscopy (TEM) image (left) and size distribution (right), (b) UV–vis spectrum, (c) FTIR spectra of Au@alendronate NPs (red curve) versus alendronate (black) curve, (d
PDF
Album
Supp Info
Letter
Published 27 Nov 2018

Site-controlled formation of single Si nanocrystals in a buried SiO2 matrix using ion beam mixing

  • Xiaomo Xu,
  • Thomas Prüfer,
  • Daniel Wolf,
  • Hans-Jürgen Engelmann,
  • Lothar Bischoff,
  • René Hübner,
  • Karl-Heinz Heinig,
  • Wolfhard Möller,
  • Stefan Facsko,
  • Johannes von Borany and
  • Gregor Hlawacek

Beilstein J. Nanotechnol. 2018, 9, 2883–2892, doi:10.3762/bjnano.9.267

Graphical Abstract
  • ambient environment, and the thickness of both layers was confirmed by cross-sectional transmission electron microscopy (TEM). Broad-beam irradiation The irradiation was performed using a 200 kV ion implanter (Danfysik Model 1090) at the Ion Beam Center of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR
  • electron microscopy (TEM) lamella preparation. In all cases, the local distribution and size of the NCs are mapped using energy-filtered transmission electron microscopy (EFTEM). Results and Discussion In Figure 1, a comparison of cross-sectional Si plasmon-loss-filtered TEM images obtained from two Si
  • , dynamic binary collision and kinetic Monte Carlo (kMC) computer simulations predict the formation of a chain of single Si NCs due to the strong reduction of the SiO2 volume in which the Si excess is sufficient for NC formation. Finally, a single Si NC embedded in SiO2 is isolated by FIB-based transmission
PDF
Album
Full Research Paper
Published 16 Nov 2018

Controlling surface morphology and sensitivity of granular and porous silver films for surface-enhanced Raman scattering, SERS

  • Sherif Okeil and
  • Jörg J. Schneider

Beilstein J. Nanotechnol. 2018, 9, 2813–2831, doi:10.3762/bjnano.9.263

Graphical Abstract
  • microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM), X-ray photoelectron (XPS and Auger) and ultraviolet–visible spectroscopy (UV–vis) as well as contact angle measurements. It was found that different morphologies of the roughened Ag films could be obtained under controlled
  • -30 FEG using an electron beam at 25 kV. Cross-sectional transmission electron microscopy (TEM) images of the silver films were recorded using a Tecnai G2 F20 microscope operating at 200 kV after the use of focused-ion beam (FIB) for sample preparation [74]. X-ray diffraction (XRD) was performed on a
PDF
Album
Supp Info
Full Research Paper
Published 07 Nov 2018

Size-selected Fe3O4–Au hybrid nanoparticles for improved magnetism-based theranostics

  • Maria V. Efremova,
  • Yulia A. Nalench,
  • Eirini Myrovali,
  • Anastasiia S. Garanina,
  • Ivan S. Grebennikov,
  • Polina K. Gifer,
  • Maxim A. Abakumov,
  • Marina Spasova,
  • Makis Angelakeris,
  • Alexander G. Savchenko,
  • Michael Farle,
  • Natalia L. Klyachko,
  • Alexander G. Majouga and
  • Ulf Wiedwald

Beilstein J. Nanotechnol. 2018, 9, 2684–2699, doi:10.3762/bjnano.9.251

Graphical Abstract
  • ), we vary the reaction temperature. The sample numbers reflect the mean magnetic NP diameter, i.e., the Fe3O4 part, in nanometers. After synthesis, all NPs were investigated by transmission electron microscopy (TEM). Figure 1 shows the corresponding images of the four NP batches: magnetite and gold NPs
PDF
Album
Supp Info
Full Research Paper
Published 16 Oct 2018

Improved catalytic combustion of methane using CuO nanobelts with predominantly (001) surfaces

  • Qingquan Kong,
  • Yichun Yin,
  • Bing Xue,
  • Yonggang Jin,
  • Wei Feng,
  • Zhi-Gang Chen,
  • Shi Su and
  • Chenghua Sun

Beilstein J. Nanotechnol. 2018, 9, 2526–2532, doi:10.3762/bjnano.9.235

Graphical Abstract
  • transmission electron microscopy (TEM). Figure 2a,b shows the NWs which have a diameter of 20–100 nm and length of 1–3 μm, and Figure 2c shows the thin NBs, with a width of 200–300 nm and a length of ≈1 μm. The selected area electron diffraction patterns (SAED), projected from the [1] zone axis of the yellow
PDF
Album
Supp Info
Full Research Paper
Published 24 Sep 2018
Other Beilstein-Institut Open Science Activities