A broadband detector based on series YBCO grain boundary Josephson junctions

  • Egor I. Glushkov,
  • Alexander V. Chiginev,
  • Leonid S. Kuzmin and
  • Leonid S. Revin

Beilstein J. Nanotechnol. 2022, 13, 325–333, doi:10.3762/bjnano.13.27

Graphical Abstract
  • characteristic, responsivity, noise, and noise-equivalent power (NEP) for a 250 GHz external signal. The optimal number of junctions to obtain the minimum NEP was found. The use of a series of junctions allows one to increase the responsivity by a factor of 2.5, the NEP value by a factor of 1.5, and the power
  • the electromagnetic analysis and numerical simulation of the broadband detector based on a series of HTSC bicrystal Josephson junctions to maximize response, power dynamic range, and noise-equivalent power. Electromagnetic Simulation Figure 1a–c shows options for the geometry of a log-periodic antenna
  • resistance RN set the same for all JJs in series. Thermal fluctuations IF are treated as white Gaussian noise with zero mean and the correlation function Q is the charge on the load capacitor calculated from the equation for the oscillatory circuit: The described model is not complete. To simulate a log
PDF
Album
Full Research Paper
Published 28 Mar 2022

Plasma modes in capacitively coupled superconducting nanowires

  • Alex Latyshev,
  • Andrew G. Semenov and
  • Andrei D. Zaikin

Beilstein J. Nanotechnol. 2022, 13, 292–297, doi:10.3762/bjnano.13.24

Graphical Abstract
  • each other, cf. Figure 4. This result clearly illustrates specific features of voltage fluctuations induced in the second wire by a QPS event in the first wire: Such fluctuations are characterized by zero average voltage and non-vanishing voltage noise [24]. Conclusion In this work we have investigated
PDF
Album
Full Research Paper
Published 04 Mar 2022

Impact of device design on the electronic and optoelectronic properties of integrated Ru-terpyridine complexes

  • Max Mennicken,
  • Sophia Katharina Peter,
  • Corinna Kaulen,
  • Ulrich Simon and
  • Silvia Karthäuser

Beilstein J. Nanotechnol. 2022, 13, 219–229, doi:10.3762/bjnano.13.16

Graphical Abstract
  • measurements on empty nanoelectrode gaps or nanoelectrode pairs only treated repeatedly with TP solution and ethanol show conductance values around 0.01 pS, corresponding to the noise level. In Figure 3 the current vs voltage graph of a typical Ru(TP)2-complex wire device (green) is given, exhibiting a low
  • reason for the missing electrical switching might be the low conductance through these devices while the expected on/off ratio of 1.5 would lead only to a minor current increase [15]. Thus, the expected electrical switching effect in these devices may be simply covered by noise. However, to discuss this
  • empty nanogaps representing the noise level (grey). Arrhenius plots. (a) Ru(TP)2-complex wire device (U = 1 V). (b) Ru(MPTP)2–AuNP device for voltages between 0.1 and 1 V. Points correspond to measurements while lines correspond to linear regressions. Current vs time traces at 1 V bias. Samples were
PDF
Album
Supp Info
Full Research Paper
Published 15 Feb 2022

Theranostic potential of self-luminescent branched polyethyleneimine-coated superparamagnetic iron oxide nanoparticles

  • Rouhollah Khodadust,
  • Ozlem Unal and
  • Havva Yagci Acar

Beilstein J. Nanotechnol. 2022, 13, 82–95, doi:10.3762/bjnano.13.6

Graphical Abstract
  • over vacuum should be generated to obtain the spatial frequency distribution in the image. Then, a noise-filtering mask from the reduced FFT preserving only the crystalline contributions from the original image should be generated to produce the filtered nanoparticle image [35]. An AFM analysis
PDF
Album
Supp Info
Full Research Paper
Published 18 Jan 2022

Measurement of polarization effects in dual-phase ceria-based oxygen permeation membranes using Kelvin probe force microscopy

  • Kerstin Neuhaus,
  • Christina Schmidt,
  • Liudmila Fischer,
  • Wilhelm Albert Meulenberg,
  • Ke Ran,
  • Joachim Mayer and
  • Stefan Baumann

Beilstein J. Nanotechnol. 2021, 12, 1380–1391, doi:10.3762/bjnano.12.102

Graphical Abstract
  • -circuit potential. For all temperatures, the relaxation took less than 40 s for negative polarization and less than 60 s for positive polarization. All relaxation curves showed a clear dependence on exponential rules, although for temperature below 250 °C, the signal-to-noise ratio was very low for the
PDF
Album
Full Research Paper
Published 15 Dec 2021

Polarity in cuticular ridge development and insect attachment on leaf surfaces of Schismatoglottis calyptrata (Araceae)

  • Venkata A. Surapaneni,
  • Tobias Aust,
  • Thomas Speck and
  • Marc Thielen

Beilstein J. Nanotechnol. 2021, 12, 1326–1338, doi:10.3762/bjnano.12.98

Graphical Abstract
  • version 7.4, Digital Surf SARL, Besançon, France) was used to analyze the CLSM measurements. After the filtering of median noise, zig-zag profile lines of at least 200 µm in length were taken on the topographic layer of each spot. A standard Gaussian filter (8 µm) was applied to the profiles in order to
PDF
Album
Supp Info
Full Research Paper
Published 01 Dec 2021

Identifying diverse metal oxide nanomaterials with lethal effects on embryonic zebrafish using machine learning

  • Richard Liam Marchese Robinson,
  • Haralambos Sarimveis,
  • Philip Doganis,
  • Xiaodong Jia,
  • Marianna Kotzabasaki,
  • Christiana Gousiadou,
  • Stacey Lynn Harper and
  • Terry Wilkins

Beilstein J. Nanotechnol. 2021, 12, 1297–1325, doi:10.3762/bjnano.12.97

Graphical Abstract
  • outcome. However, the analysis of Cortes-Ciriano and Bender [36], whilst not identical to the analysis performed here, found that adding noise, of the same magnitude considered in the current study, to the descriptors did allow data augmentation to improve the performance of Random Forest models. The
  • previous studies [36], reflects the descriptors involved. Hence, future studies should investigate whether adding different levels of noise to different kinds of descriptors, such as the novel descriptors discussed above, would offer improved performance. Separately, one particularly interesting finding of
PDF
Album
Supp Info
Full Research Paper
Published 29 Nov 2021

Cantilever signature of tip detachment during contact resonance AFM

  • Devin Kalafut,
  • Ryan Wagner,
  • Maria Jose Cadena,
  • Anil Bajaj and
  • Arvind Raman

Beilstein J. Nanotechnol. 2021, 12, 1286–1296, doi:10.3762/bjnano.12.96

Graphical Abstract
  • on how the cantilever motion evolves when this essential condition is violated. This is not an uncommon occurrence since higher operating amplitudes tend to yield better signal-to-noise ratio, so users may inadvertently reduce their experimental accuracy by inducing tip–sample detachment in an effort
  • methods provide information on important mechanical and electrical properties across a wide variety of samples. CR-AFM, PFM, and ESM are built upon the fundamental assumption that as the cantilever is excited, the probe tip remains in contact with the sample. Signal-to-noise ratios in these measurements
PDF
Album
Supp Info
Full Research Paper
Published 24 Nov 2021

Nonmonotonous temperature dependence of Shapiro steps in YBCO grain boundary junctions

  • Leonid S. Revin,
  • Dmitriy V. Masterov,
  • Alexey E. Parafin,
  • Sergey A. Pavlov and
  • Andrey L. Pankratov

Beilstein J. Nanotechnol. 2021, 12, 1279–1285, doi:10.3762/bjnano.12.95

Graphical Abstract
  • temperatures down to sub-kelvin, such as the phase diffusion regime [1][2][3], evidence for a minigap [4], and low-noise nano-junctions [5]. Such abilities raise not only fundamental interest in HTSC JJs but also an active search for ways to practically use such JJs. In recent years, the limiting
  • by the resistively–capacitively shunted-junction (RCSJ) model [25][26], especially for measurements obtained at high temperatures. However, taking into account the effect of the YBCO junction resistance thermal noise [16] makes it possible to neutralize this difference and obtain a good agreement
  • through an optical window with IR filters using a semiconductor synthesizer with a multiplier (70–78 GHz) or using a backward wave oscillator (230–370 GHz). The JJ transport properties and the response were characterized by a precise Keithley low-noise current source and nanovoltmeter using a standard 4
PDF
Album
Full Research Paper
Published 23 Nov 2021

A review on slip boundary conditions at the nanoscale: recent development and applications

  • Ruifei Wang,
  • Jin Chai,
  • Bobo Luo,
  • Xiong Liu,
  • Jianting Zhang,
  • Min Wu,
  • Mingdan Wei and
  • Zhuanyue Ma

Beilstein J. Nanotechnol. 2021, 12, 1237–1251, doi:10.3762/bjnano.12.91

Graphical Abstract
  • . The inset illustrates similar contact angles (around 87°) of water on both surfaces. Figure 3 was redrawn from [69]. Variation of negative slip length values with an external driving force. The uncertainty of the MD simulation results come from the noise of the data points. Figure 4 was redrawn from
PDF
Album
Review
Published 17 Nov 2021

Two dynamic modes to streamline challenging atomic force microscopy measurements

  • Alexei G. Temiryazev,
  • Andrey V. Krayev and
  • Marina P. Temiryazeva

Beilstein J. Nanotechnol. 2021, 12, 1226–1236, doi:10.3762/bjnano.12.90

Graphical Abstract
  • that errors in choosing this parameter can lead to image distortion and noise, as well as damage to the probe. It can be seen from the foregoing that the choice of scanning parameters depends on both the characteristics of the sample and the sharpness of the probe. Optimization, as a rule, requires a
  • , and in order to reach the A1 level, it is necessary to bring the probe closer to the surface. Let us consider the main advantages of this method. One is the adaptive scanning speed. The levels of A1 and A2 may be very close. Their difference should only be much higher than the noise level. In our
PDF
Album
Supp Info
Full Research Paper
Published 15 Nov 2021

The effect of cobalt on morphology, structure, and ORR activity of electrospun carbon fibre mats in aqueous alkaline environments

  • Markus Gehring,
  • Tobias Kutsch,
  • Osmane Camara,
  • Alexandre Merlen,
  • Hermann Tempel,
  • Hans Kungl and
  • Rüdiger-A. Eichel

Beilstein J. Nanotechnol. 2021, 12, 1173–1186, doi:10.3762/bjnano.12.87

Graphical Abstract
  • -noise ratio (co-addition mode). The resulting spectra were analysed by fitting a Lorentz distribution and a Breit–Wigner–Fano distribution, as explained in detail in [12]. For the elemental analysis 2 mg of sample was burned in the elemental analyser (VarioelCube, Elementar) for both CHN and O analyses
PDF
Album
Supp Info
Full Research Paper
Published 19 Oct 2021

A new method for obtaining model-free viscoelastic material properties from atomic force microscopy experiments using discrete integral transform techniques

  • Berkin Uluutku,
  • Enrique A. López-Guerra and
  • Santiago D. Solares

Beilstein J. Nanotechnol. 2021, 12, 1063–1077, doi:10.3762/bjnano.12.79

Graphical Abstract
  • above restriction of the Fourier transform by applying time derivatives to the experimental quantities and making use of its well-known mathematical properties [29], but although the approaches are theoretically feasible, the existence of noise in AFM signals generally precludes their successful
  • material and its relationship to the modified harmonic components should also be investigated further. One final area of future work concerns the effect of electronic or thermal noise on the quality of the viscoelastic analysis. Generally speaking, analyses in the complex domain can handle noise more
  • robustly than analyses in the time domain, especially when specific features are expected in the plots of the viscoelastic functions. For example, the fact that in the Kelvin–Voigt model, non-zero-centered peaks are not expected in the storage compliance (see Figure 11) could be used to discriminate noise
PDF
Album
Supp Info
Full Research Paper
Published 23 Sep 2021

A Au/CuNiCoS4/p-Si photodiode: electrical and morphological characterization

  • Adem Koçyiğit,
  • Adem Sarılmaz,
  • Teoman Öztürk,
  • Faruk Ozel and
  • Murat Yıldırım

Beilstein J. Nanotechnol. 2021, 12, 984–994, doi:10.3762/bjnano.12.74

Graphical Abstract
  • detectivity represents the inverse of the noise equivalent power [32]. Both responsivity and specific detectivity increased with increasing illumination power density and confirmed the good performance of the fabricated Au/CuNiCoS4/p-Si photodiode. This behavior was studied and discussed in the literature for
PDF
Album
Full Research Paper
Published 02 Sep 2021

Uniform arrays of gold nanoelectrodes with tuneable recess depth

  • Elena O. Gordeeva,
  • Ilya V. Roslyakov,
  • Alexey P. Leontiev,
  • Alexey A. Klimenko and
  • Kirill S. Napolskii

Beilstein J. Nanotechnol. 2021, 12, 957–964, doi:10.3762/bjnano.12.72

Graphical Abstract
  • diffusion layers results in the planar diffusion to the NEA surface. Thus, a decrease in the density of active electrodes could be more appropriate because of the decrease in electric double layer charging current and, as a consequence, the growth of the signal-to-noise ratio. A controlled decrease in the
PDF
Album
Full Research Paper
Published 30 Aug 2021

The role of convolutional neural networks in scanning probe microscopy: a review

  • Ido Azuri,
  • Irit Rosenhek-Goldian,
  • Neta Regev-Rudzki,
  • Georg Fantner and
  • Sidney R. Cohen

Beilstein J. Nanotechnol. 2021, 12, 878–901, doi:10.3762/bjnano.12.66

Graphical Abstract
  • standard image processing techniques, kernel filters exist for functions such as edge detection, edge enhancement, noise reduction, and smoothing. In contrast, in CNNs, the parameters of the filters are not known a priori and the CNN model learns the best parameters during the training process to extract
  • , decision making is strongly influenced by random noise and meaningless trends in the training data. This boosts performance on the training dataset, but results in poor generalization to new data. There are several approaches that can reduce over-fitting. Increasing the sample data set size helps reduce
  • ][94], beginning with the more abundant examples of optical and electron microscopy, which will later be compared and contrasted with applications in SPM [95]. Strategies for obtaining training data Successful application of deep learning relies on the quality (e.g. signal/noise, resolution, and
PDF
Album
Review
Published 13 Aug 2021

Comprehensive review on ultrasound-responsive theranostic nanomaterials: mechanisms, structures and medical applications

  • Sepand Tehrani Fateh,
  • Lida Moradi,
  • Elmira Kohan,
  • Michael R. Hamblin and
  • Amin Shiralizadeh Dezfuli

Beilstein J. Nanotechnol. 2021, 12, 808–862, doi:10.3762/bjnano.12.64

Graphical Abstract
PDF
Album
Review
Published 11 Aug 2021

Reducing molecular simulation time for AFM images based on super-resolution methods

  • Zhipeng Dou,
  • Jianqiang Qian,
  • Yingzi Li,
  • Rui Lin,
  • Jianhai Wang,
  • Peng Cheng and
  • Zeyu Xu

Beilstein J. Nanotechnol. 2021, 12, 775–785, doi:10.3762/bjnano.12.61

Graphical Abstract
  • factors to 2× (25 × 25) and 3× (17 × 17), respectively, to construct super-resolution images. The peak signal to noise ratio (PSNR, expressed as the logarithmic decibel scale) and structural similarity (SSIM, value range is [0,1]) are used to evaluate the quality of the reconstructed image. The PSNR is
PDF
Album
Full Research Paper
Published 29 Jul 2021

Recent progress in magnetic applications for micro- and nanorobots

  • Ke Xu,
  • Shuang Xu and
  • Fanan Wei

Beilstein J. Nanotechnol. 2021, 12, 744–755, doi:10.3762/bjnano.12.58

Graphical Abstract
  • that might occur with other methods, such as heat and noise. Using this method, Uvet and others provided an innovative micro-UFO, which was suspended by diamagnetic levitation. After the micro-UFO reached a certain height, it could successfully track the maximum range of motion of the linear stage of
PDF
Album
Review
Published 19 Jul 2021

Electromigration-induced formation of percolating adsorbate islands during condensation from the gaseous phase: a computational study

  • Alina V. Dvornichenko,
  • Vasyl O. Kharchenko and
  • Dmitrii O. Kharchenko

Beilstein J. Nanotechnol. 2021, 12, 694–703, doi:10.3762/bjnano.12.55

Graphical Abstract
  • -correlated Gaussian noise: ⟨ξ(r,t)⟩ = 0, ⟨ξ(r,t)ξ(r’,t’)⟩ = σ2δ(r− r’)(t − t’); σ2 is the intensity of fluctuations. This source takes into account the effects of redistribution of adatoms at the microscopic level, describing the system at the mesoscopic level. Reaction term During condensation processes
PDF
Album
Letter
Published 13 Jul 2021

A review of defect engineering, ion implantation, and nanofabrication using the helium ion microscope

  • Frances I. Allen

Beilstein J. Nanotechnol. 2021, 12, 633–664, doi:10.3762/bjnano.12.52

Graphical Abstract
PDF
Album
Review
Published 02 Jul 2021

Determining amplitude and tilt of a lateral force microscopy sensor

  • Oliver Gretz,
  • Alfred J. Weymouth,
  • Thomas Holzmann,
  • Korbinian Pürckhauer and
  • Franz J. Giessibl

Beilstein J. Nanotechnol. 2021, 12, 517–524, doi:10.3762/bjnano.12.42

Graphical Abstract
  • . Note that the program will not converge to a solution if eLIM is too small because of noise and factors such as drift. Another problem is the choice of starting values. To try different combinations with equal probability, random starting values within a definable interval were generated. Care has to
PDF
Album
Supp Info
Full Research Paper
Published 01 Jun 2021

Intracranial recording in patients with aphasia using nanomaterial-based flexible electronics: promises and challenges

  • Qingchun Wang and
  • Wai Ting Siok

Beilstein J. Nanotechnol. 2021, 12, 330–342, doi:10.3762/bjnano.12.27

Graphical Abstract
  • has an excellent temporal resolution at the millisecond scale. ECoG data have a typical sampling rate of 1,000–3,000 Hz. This high temporal resolution offers an opportunity to observe the rapid dynamics of neural activities in precisely localized brain regions. ECoG has a much higher signal-to-noise
  • ratio (SNR) than other modalities, such as fMRI or scalp EEG. The SNR of ECoG is 100 times higher than that of scalp EEG due to the reduction of environmental and physiological noise such as muscle contractions or skin potentials [42][46]. ECoG electrodes are characterised by a circular plate shape
  • -noise ratio (Figure 5c, right). The real-time signals of cortical activities in different medical and drug-induced epileptic states were precisely measured when the iWEBS array was used in freely moving mice. Combined with optogenetic mapping techniques, long-range cortical interactions were
PDF
Album
Review
Published 08 Apr 2021

The patterning toolbox FIB-o-mat: Exploiting the full potential of focused helium ions for nanofabrication

  • Victor Deinhart,
  • Lisa-Marie Kern,
  • Jan N. Kirchhof,
  • Sabrina Juergensen,
  • Joris Sturm,
  • Enno Krauss,
  • Thorsten Feichtner,
  • Sviatoslav Kovalchuk,
  • Michael Schneider,
  • Dieter Engel,
  • Bastian Pfau,
  • Bert Hecht,
  • Kirill I. Bolotin,
  • Stephanie Reich and
  • Katja Höflich

Beilstein J. Nanotechnol. 2021, 12, 304–318, doi:10.3762/bjnano.12.25

Graphical Abstract
  • modulation setup. The spatial displacement of the focus modulates the signal [61] and the lock-in coupled detector provides an excellent signal-to-noise ratio for individual small scatterers. Figure 7d–f shows the extinction (sum of scattering and absorption) spectra corresponding to the tetramers in Figure
PDF
Album
Supp Info
Full Research Paper
Published 06 Apr 2021

Scanning transmission helium ion microscopy on carbon nanomembranes

  • Daniel Emmrich,
  • Annalena Wolff,
  • Nikolaus Meyerbröker,
  • Jörg K. N. Lindner,
  • André Beyer and
  • Armin Gölzhäuser

Beilstein J. Nanotechnol. 2021, 12, 222–231, doi:10.3762/bjnano.12.18

Graphical Abstract
  • capability is the ability to record charge-compensated images on insulating samples such as biological specimen or polymers without requiring a conductive coating layer [2][3][4]. In addition, the ability to record images with high signal-to-noise ratio while using low beam currents (the HIM creates up to
  • for ion microscopes. The dark-field STIM detector enables the imaging of very thin carbon nanomembranes with a high signal-to-noise ratio, which could not be achieved using the conventional ETD detector in the HIM. The evaluation of the contrast mechanism suggests that the detector is suitable for end